Sr. Controls Engineer - Commissioning
Northmark
·Today
- Location
- Dallas-Victory Commons, United States of America
- Workplace
- Onsite
- Type
- Full-time
- Department
- Engineering
- Seniority
- Senior
- Experience
- 8+ years
- Education
- Bachelor
- Visa
- Not sponsored
- Source
- Workday
Description
The Company
NorthMark Compute & Cloud (NMC²) is backed by dedicated leadership and investment, with a clear mission as it operates at the bleeding edge of technology. Its goal is to scale and enhance the high-performance computing (HPC) and cloud infrastructure that supports its clients' research, production, and delivery, enabling breakthroughs that shape the industries of tomorrow. Its engineers build critical infrastructure to eliminate friction in scientific research, simulations, analysis, and decision-making, accelerating discovery and driving faster innovation.
The Position
This role exists to verify, test, and be personally accountable for proving that the automated control systems governing a data center's electrical power and cooling infrastructure function exactly as designed before the facility is placed into live operation. Where the design engineer of record establishes the architecture and sequences of operation on paper, the Senior Controls Engineer - Commissioning ensures those systems perform correctly under real-world, high-stress conditions - including simulated utility loss, generator start, load transfer, and cooling failover - so that redundancy and failover claims are demonstrated, not assumed. This role reports to the SME / Design Authority.
This role owns the commissioning (Cx) strategy from control system architecture verification through Level 5 Integrated Systems Testing (IST) and final operational handover and is the technical bridge between the design intent captured in the Sequence of Operation (SOO) and the as-built, as-tested behavior of the BMS, EPMS, and SCADA/EMS control network. It exists because a redundancy or failover claim that has not been scripted, tested, and witnessed at the appropriate commissioning level is not a verified engineering property - it is an assumption that surfaces, at best, during commissioning, and at worst, during a live incident in operation.
Responsibilities
Control System Architecture & Quality Verification
- Validate the integration of the Building Management System (BMS) and Electrical Power Monitoring System (EPMS) to ensure complete, accurate visibility over electrical and mechanical infrastructure for the operations team
- Perform point-to-point verification, software/logic testing, and graphical user interface (UI) checks to confirm sensor data, alarms, and control states display accurately and match the as-built field condition
- Partner with IT and the Controls/Cybersecurity Engineer to confirm control networks are securely segmented and isolated, and that the SCADA/EMS architecture aligns with IEC 62443 or NIST-based cybersecurity requirements
- Review control system architecture and instrumentation specifications during early design to catch network topology or sensor-placement flaws before equipment procurement - the earliest and cheapest point to correct them
Commissioning (Cx) Strategy Development
- Author detailed, step-by-step commissioning scripts and checklists covering Level 1 through Level 5 (L1–L5) data center testing phases, consistent with ASHRAE Guideline 0 commissioning process methodology
- Review and refine the Sequence of Operation (SOO) to confirm automated responses trigger correctly during equipment failure, loss of utility, and failover scenarios - before those sequences are relied upon in a live test
- Develop Methods of Procedure (MOPs) and Standard Operating Procedures (SOPs) governing safe testing in live electrical environments, coordinated with NFPA 70E requirements for any work performed energized or near energized equipment
- Define acceptance criteria and pass/fail thresholds for each commissioning level before testing begins, so results are evaluated against a pre-agreed standard rather than a judgment call made in the field
Execution of Level 4 & Level 5 Testing
- Execute Level 4 (Functional Performance Testing) on standalone control systems, confirming chillers, pumps, generators, and UPS units respond correctly to individual control loops and setpoint changes
- Plan and orchestrate Level 5 (Integrated Systems Testing / IST), including full-scale simulated utility blackout events, to prove the control system automatically starts generation, transfers electrical load, and sustains continuous cooling without manual intervention
- Validate high-density liquid cooling loop controls and advanced GPU cluster cooling sequences as part of IST scope, reflecting current AI/high-density infrastructure requirements
- Confirm IST scenarios explicitly exercise the redundancy target (N+1, N+2, or 2N) established at design — loss of a single generation or cooling unit under load - so the commissioning result is the direct proof point of the design's FMEA claim, not a separate exercise
Issue Resolution & Root-Cause Analysis
- Diagnose control system failures during construction and testing, including Loss of Visibility (LOV) events, PLC communication drops, and BMS/EPMS integration faults, and drive root-cause resolution rather than symptomatic fixes
- Log, track, and manage the commissioning punch list with contractors and vendors through closure, ensuring no life-safety or redundancy-critical item is closed without documented retest evidence
- Flag and escalate any commissioning finding that touches a hard-blocking criterion (NFPA 70/70E, UL listing, redundancy/FMEA, or cybersecurity) immediately, per the project's RFI/Submittal escalation path - a commissioning-stage discovery does not get resolved on verbal assurance
Final Handover & Operations Readiness
- Compile Systems Manuals, commissioning reports, and validation records sufficient to satisfy compliance requirements, LEED documentation goals, and the project's Gate 4/5 closeout package
- Train the on-site operations team on control system graphics navigation, active alarm management, and manual override procedures for emergency conditions
- Support and validate the live demonstrated failover (loss of a prime generation or cooling unit under load, with no interruption to critical load) at Gate 5 as the terminal proof point of the commissioning program
Gate & Milestone Accountability
- Gate 3 (Design Freeze): Review the SOO, controls architecture, and cybersecurity risk assessment for testability - confirm the design can be commissioned as specified before it is frozen
- Gate 4 (Validation & Commissioning Readiness): Own the commissioning plan and confirm it covers all redundancy failover scenarios to be tested, FAT results are acceptable with no open safety issues, and punch list items are non-safety-critical or have documented closure plans
- Gate 5 (Final Acceptance/Handover): Deliver the demonstrated live failover under load and complete documentation/training package required for operational handover
Requirements
- Bachelor of Science in Controls Engineering, Electrical Engineering, Mechanical Engineering, or a closely related discipline from an ABET-accredited program (or equivalent international accreditation) is required
- Professional Engineer (PE) license is required, or actively in progress with an expectation of licensure within a defined period; jurisdictions requiring a PE stamp on permit submittals make this a functional requirement of the role, not a preference
- Certified Commissioning Authority (CxA) credential (e.g., through ASHRAE, BCA, or AABC Commissioning Group) is strongly preferred
- Working knowledge of ASHRAE Guideline 0 (commissioning process) and Guideline 1.1 (HVAC Cx process) is required; formal training or certification in these is preferred
- NFPA 70E Arc-Flash / Electrical Safety certification is required given routine work in or near live electrical environments during testing
- Platform-specific certification on one or more major BMS/EPMS platforms (Ignition, ABB 800xa, Schneider, Johnson Controls, Allen-Bradley) is preferred
- Additional training or certification in IEC 62443 industrial cybersecurity fundamentals is preferred, given routine coordination with the Controls/Cybersecurity Engineer on SCADA/EMS network segmentation
- Direct Level 5 IST execution experience. Typically, 8–10+ years of controls engineering experience, with demonstrated, hands-on experience planning and executing full-scale Integrated Systems Testing - including simulated utility blackout events - on mission-critical or data center facilities, not solely functional (Level 4) point-testing experience
- BMS/EPMS platform depth. Demonstrated experience validating BMS and EPMS integration across multiple vendor platforms, including point-to-point verification, logic testing, and graphics/UI validation against as-built field conditions
- SOO fluency and failure-mode literacy. A track record of reviewing and refining Sequences of Operation to confirm automated failover behavior is correct as written - before it is relied upon in a live test - and of tracing commissioning results back to the design's FMEA/redundancy claim
- Root-cause diagnostic skill under field conditions. Experience independently diagnosing control system failures (LOV events, PLC communication faults, integration errors) during construction and startup and driving root-cause resolution with contractors and vendors rather than accepting a symptomatic fix
- Comfort holding a hard line at commissioning. Experience escalating a commissioning-stage finding that touches a hard-blocking safety, code, or cybersecurity criterion, and refusing to close a punch list item on verbal assurance in place of documented retest evidence - even under schedule pressure to reach handover
- High-density/AI infrastructure exposure. Familiarity with validating high-density liquid cooling loop controls and GPU cluster cooling sequences is strongly preferred, reflecting current data center infrastructure trends
- Data center or mission-critical facility experience. Prior experience commissioning data center, hyperscale, colocation, or other mission-critical infrastructure is strongly preferred, given the liability profile and uptime expectations specific to this asset class
- Communication and training range. Demonstrated ability to write commissioning documentation precise enough for a test technician to execute unambiguously, and to train operations personnel - a materially different communication skill than design documentation aimed at other engineers
It is impossible to list every requirement for, or responsibility of, any position. Similarly, we cannot identify all the skills a position may require since job responsibilities and the Company’s needs may change over time. Therefore, the above job description is not comprehensive or exhaustive. The Company reserves the right to adjust, add to or eliminate any aspect of the above description. The Company also retains the right to require all employees to undertake additional or different job responsibilities when necessary to meet business needs.
Must be legally authorized to work in the United States without the need for employer sponsorship, now or at any time in the future.
Benefits & Perks:
Company-Paid Lunch Stipend: Lunch is provided via GrubHub
Company-Paid Benefits: 100% Employer-Paid Medical in our High Deductible Health Plan, Dental and Vision benefits for employees and their families, 16 weeks of Paid Parental Leave, Employee Assistance Program, Life insurance, Short-Term Disability and Long-Term Disability
401(k): Company will match 100% of your contributions up to 6%
Optional Employee-Paid Benefits: Medical insurance in our PPO plan and a variety of other benefits such as Health Savings Accounts (with Company Contribution!), Flexible Spending Accounts, Supplemental Life Insurance, Wellhub and more.
Time Off: 25 days of Paid Time Off plus 12 company holidays
EQUAL OPPORTUNITY EMPLOYER
NORTHMARK STRATEGIES LLC IS AN EQUAL EMPLOYMENT OPPORTUNITY EMPLOYER. THE COMPANY'S POLICY IS NOT TO DISCRIMINATE AGAINST ANY APPLICANT OR EMPLOYEE BASED ON RACE, COLOR, RELIGION, NATIONAL ORIGIN, GENDER, AGE, SEXUAL ORIENTATION, GENDER IDENTITY OR EXPRESSION, MARITAL STATUS, MENTAL OR PHYSICAL DISABILITY, AND GENETIC INFORMATION, OR ANY OTHER BASIS PROTECTED BY APPLICABLE LAW. THE FIRM ALSO PROHIBITS HARASSMENT OF APPLICANTS OR EMPLOYEES BASED ON ANY OF THESE PROTECTED CATEGORIES.